Lets learn about vision boards
THE SUCCESS FORMULA
THE SUCCESS FORMULA
SIMPLE 3 STEP PROCESS
SIMPLE 3 STEP PROCESS
STRUCTURAL AUDITING
COMPLETE SOLUTION FOR STRUCTURAL CRACKS, DISTRESS BY STRUCTURAL AUDITS AND PMC

COMPLETED
10,000+ PROJECTS
Aaryan offers complete end-to-end consulting services, covering structural testing, inspection, audits and certification. Our systems are time-tested and proven. We undertake projects that require either a complete scope or a part of our expert services. Working as a team, we are always with our clients to ensure they get the best techno-commercial solution from Aaryan. Waterproofing failures often lead to structural problems and vice versa. Aaryan provides a holistic approach to solve both together
DETAILED REQUIREMENT CAPTURE
START RIGHT BY ACCURATELY DEFINING TECHNO COMMERCIAL REQUIREMENT
Capturing the requirement in detail is the key aspect of starting any project. the budget, warranty, constraints, and operational parameters are all defined over here.

PRELIMINARY REQUIREMENT ANALYSIS
DETAILED SITE ASSESSMENT REPORT DELIVERED COMPLIMENTARY

Preliminary site visit, followed by key findings are done in this phase. A detailed report with photographs and key parameters are documented and given to the client as a site assessment report*. For select sites, we offer this service complimentary.
NON DESTRUCTIVE TESTING
MORE THAN 21 TESTS TO ASSESS THE CONDITION OF THE STRUCTURE
80 percent of structures are just inspected and not tested, putting safety and durability at risk! Typically offered for old concrete structures in pre repair/ audit stage to - We have special packages for NDT with condition survey for structural consultants.

CONDITIONS SURVEY REPORT BY CORELATING VISUAL INSPECTION AND TEST RESULTS
CONDITION SURVEY REPORT

Evaluate the overall condition of structures by correlation of NDT test results and observations. This classified structures into mildly/ moderately/ severely/ damaged or in the worst case are recommended for demolition.
BILL OF QUANTITIES
BILL OF QUANTITIES BACKED BY METHODOLOGY AND TAKE OFF SHEETS
Detailed Bill of Quantities for structural repairs and restoration


REPAIR WITH ASSURED QUALITY
ASSESSMENT OF EFFECTIVE EXECUTION OF STRUCTURAL REPAIRS ENSURE VALUE FOR MONEY
RAQ includes a quality check for the effective execution of structural repairs with non-destructive testing methods. Raw Material quality, Comparison of pre and post-NDT test results is used to assess the effectiveness of repairs. Specifications for corrective action if any is provided.

STRUCTURAL STABILITY CERTIFICATE
ISSUE OF STRUCTURAL STABILITY CERTIFICATE BY QUALIFIED PROFESSIONALS
Structural Stabillity certificate is issued after a thourough check by licensed engineers.
REDESIGN OF STRUCTURE
REDESIGN FOR ALTERED USAGE OF STRUCTURE
Redesign the structure based on cutting-edge design software and a strengthening scheme that takes care of today's and future needs.

STRUCTURAL LOAD TESTS
POST REPAIR, ASSESS THE LOAD BEARING CAPACITY OF STRUCTURE TO CONFIRM THE TRANSLATION OF DESIGN INTO EXECUTION
Load tests with specified loading intensity are conducted on Bridges, Warehouse floors, Slabs, Podiums, Helipads, Escalators and more.


PREVENTIVE MAINTENANCE PLAN
IMPROPER PREVENTIVE MAINTENANCE PLANS LEAD TO FASTER DETERIORATION OF STRUCTURES
A detailed preventive measures list with periodic testing.
WATERPROOFING
COMPLETE SOLUTION TO LEAKAGES BY WATERPROOFING AUDITS AND PMC
Aaryan offers complete end-to-end consulting services, covering basement waterproofing, roof waterproofing, bathroom waterproofing, external wall waterproofing, using the latest waterproofing products and systems, evaluation of competent waterproofing contractors, supervision of works and ultimately a certification process. Waterproofing failures often lead to structural problems and vice versa. Aaryan provides a holistic approach to solve both together.


USING STATE OF THE ART EQUIPMENT
LOCATING THE SOURCE OF WATER LEAKAGE
Combining over 20 different instruments ranging from thermal cameras, moisture meters, locators, and acoustic instruments, our team has the expertise to locate the source of water leakage to a reasonable degree of accuracy.
CAPTURING REQUIREMENTS ACCURATELY
ESTABLISHING WATER PROOFING SYSTEM REQUIREMENT
Audit waterproofing to check current leaks, materials, warranty, measurement sheets, with on-site tests and analysis


EACH SYSTEM IN UNIQUE TO THE SITE
IDENTIFICATION OF IDEAL TECHNO COMMERCIAL SYSTEM SUITABLE FOR THE REQUIREMENT
Selection of the right waterproofing system to meet current and future requirements
MAPPING SYSTEM TO MANUFACTURER
SELECTION OF MANUFACTURER PROVIDING THE SELECTED SYSTEM


EM-PANELED APPLICATORS
EVALUATION OF AUTHORIZED APPLICATORS EXPERIENCED IN THE SYSTEM
Recommend the set of applicators experienced in executing system of the selected manufacturer
EXTENSIVE CHECKLIST
SUPERVISION OF EXECUTION WITH PERIODIC VISITS AT KEY MILESTONES
Periodic inspection by experts and engineers. Action points monitoring by back office for compliance

STATE OF THE ART INSTRUMENTS
PERIODIC TESTING OF WORKS AND MEASUREMENTS

Extensive periodic tests to measure and monitor the execution by applicator along with the manufacturer
COMPLIANCE STATEMENT
CERTIFICATION OF SUCCESSFUL COMPLETION OF WORKS
Collect extensive site data, inspection reports, test reports for issuing water proofing certification.


DEFINED CHECKLIST FOR MONTHS, QUARTER AND YEAR
PREVENTIVE MAINTENANCE METHODS PROTOCOL
Periodic testing post application, twice a year to ascertain the effectiveness of system. Issues if any are promptly actioned.
PERIODIC CHECKS
PERIODIC EVALUATION OF WATERPROOFING SYSTEM
Periodic checking of weak spots especially pre monsoon to preempt and take preventive action well in time.

AS BUILT DRAWINGS
AS BUILT ARCHITECTURAL AND STRUCTURAL DRAWINGS

Any structural or layout change in the building needs a proper structural drawing to ensure that the modification does not cause any stability issues to the structure.
Most of the old structures don't have any drawings on them. Some have only layout plans. There is a requirement for creating as-built drawings for these structures.
With its range of instruments like total station, rebar scanners, laser meters etc. Aaryan site team prepares as-built architectural and structural drawings, that represent the as-is condition of the building.
Aaryan as-built drawings are used by leading consulting firms, clients and statutory bodies for further analysis and decision-making.
CEILING AUDIT
YOU CAN SAVE A LIFE BY AUDITING THE CONDITION OF THE SLAB
(HIDDEN ABOVE THE FALSE CEILING)
The condition of the ceiling is a major cause of concern as it is prone to falling and injuring the people seriously occupying the space. A chunk of concrete falling from a height of 3 meters (10 feet), weighing a few kgs, can have potentially fatal consequences.
As the reinforcement gets corroded, it pushes the concrete in an outward direction. With a thin cover concrete (the space between the concrete surface and rebar), the chances of concrete falling off the ceiling increase exponentially with corrosion.
The primary reason for corrosion acceleration is age, carbonation and leakages.
Aaryan has a unique method to conduct ceiling audits for exposed ceilings and the ones that are covered with false ceilings to ensure the safety of the occupants. this includes visual inspection and special acoustic instruments to assess hard-to-reach areas. At times, co-relation with thermal inspection is also done.
We recommend that ceiling audits be done near all wet areas, common areas and areas prone to leakages. Buildings that are old, are also in urgent need of ceiling audits as a chunk of concrete could fall on someones head anytime.

RENOVATION AUDIT
ENSURE STRUCTUAL AND WATERPROOFING INTEGRITY DURING RENOVATIONS

Renovations by members can damage the structural elements, putting the residents at risk. The waterproofing done by local agencies can cause permanent leakages for other residents. This creates a headache for the building administration and management team.
Aaryan's in-depth renovation audit ensures that no structural element is damaged and waterproofing is done as per quality standards.
Using NDT test instruments and drawings, not just by visual observations, Aaryan delivers quality reports that are actionable by residents.
FORENSIC AUDIT OF BUILDINGS
ROOT CAUSE ANLAYSIS TO DETERMINE REASON OF FAILURE
A disaster like fire, cyclone, loading, vibrations or ageing can damage the structure beyond repair and give rise to claims and counter-claims for losses incurred. With insurance agencies, brokers, surveyors, and technical experts involved, the forensic analysis conducted by Aaryan provides a correct assessment of the root cause of the damage.
Depending on the inclusions and exclusions of the insurance policy, the claims are then validated by surveyors and settled by insurance companies.
Aaryan works with leading insurance companies to provide its services in areas related to claims that involve structural, waterproofing, HVAC, stp, plumbing, electrical, and lift-related cases.

STRUCTURAL STRENGTHENING
FOR CHANGE OF USE, ADDITIONAL FLOORS, INCREASED LOADING

As requirements for the use of space change, the loading on the structure also changes. Typical examples are the installation of new machinery, change of use of a building from say residential to commercial, and addition of floors.
Sometimes, the original drawings are not available. In this case, Aaryan generates the as-built drawings from scratch using its "As Built drawing system"
The modeling is done on an as-is basis and then on a to-be basis. the gaps in the modeling are then converted to a strengthening scheme, which is optimized for costs and performance.
With our in-house testing and systems, Aaryan provides an end-to-end system for structural strengthening for your structures.