top of page

STRUCTURAL AUDITING

COMPLETE SOLUTION FOR STRUCTURAL CRACKS, DISTRESS BY STRUCTURAL AUDITS AND PMC

Architect Checking Plans

COMPLETED
10,000+ PROJECTS

Aaryan offers complete end-to-end consulting services, covering structural testing, inspection, audits and certification. Our systems are time-tested and proven. We undertake projects that require either a complete scope or a part of our expert services. Working as a team, we are always with our clients to ensure they get the best techno-commercial solution from Aaryan. Waterproofing failures often lead to structural problems and vice versa. Aaryan provides a holistic approach to solve both together

DETAILED REQUIREMENT CAPTURE

START RIGHT BY ACCURATELY DEFINING TECHNO COMMERCIAL REQUIREMENT

Capturing the requirement in detail is the key aspect of starting any project. the budget, warranty, constraints, and operational parameters are all defined over here.

AARYAN PIC1.webp

PRELIMINARY REQUIREMENT ANALYSIS

DETAILED SITE ASSESSMENT REPORT DELIVERED COMPLIMENTARY

AARYAN PIC 2.webp

Preliminary site visit, followed by key findings are done in this phase. A detailed report with photographs and key parameters are documented and given to the client as a site assessment report*. For select sites, we offer this service complimentary. 

NON DESTRUCTIVE TESTING

MORE THAN 21 TESTS TO ASSESS THE CONDITION OF THE STRUCTURE

80 percent of structures are just inspected and not tested, putting safety and durability at risk! Typically offered for old concrete structures in pre repair/ audit stage to - We have special packages for NDT with condition survey for structural consultants.

Male Scientist

CONDITIONS SURVEY REPORT BY CORELATING VISUAL INSPECTION AND TEST RESULTS

CONDITION SURVEY REPORT

Field Survey

Evaluate the overall condition of structures by correlation of NDT test results and observations. This classified structures into mildly/ moderately/ severely/ damaged or in the worst case are recommended for demolition.

BILL OF QUANTITIES

BILL OF QUANTITIES BACKED BY METHODOLOGY AND TAKE OFF SHEETS

Detailed Bill of Quantities for structural repairs and restoration

AARYAN PIC 3.webp
AARYAN PIC 4.webp

REPAIR WITH ASSURED QUALITY

ASSESSMENT OF EFFECTIVE EXECUTION OF STRUCTURAL REPAIRS ENSURE VALUE FOR MONEY

RAQ includes a quality check for the effective execution of structural repairs with non-destructive testing methods. Raw Material quality, Comparison of pre and post-NDT test results is used to assess the effectiveness of repairs. Specifications for corrective action if any is provided.

AARYAN PIC 6.webp

STRUCTURAL STABILITY CERTIFICATE

ISSUE OF STRUCTURAL STABILITY CERTIFICATE BY QUALIFIED PROFESSIONALS

Structural Stabillity certificate is issued after a thourough check by licensed engineers.

REDESIGN OF STRUCTURE

REDESIGN FOR ALTERED USAGE OF STRUCTURE

Redesign the structure based on cutting-edge design software and a strengthening scheme that takes care of today's and future needs.

AARYAN PIC 5.webp

STRUCTURAL LOAD TESTS

POST REPAIR, ASSESS THE LOAD BEARING CAPACITY OF STRUCTURE TO CONFIRM THE TRANSLATION OF DESIGN INTO EXECUTION

Load tests with specified loading intensity are conducted on Bridges, Warehouse floors,  Slabs, Podiums, Helipads,  Escalators and more.

Reviewing Construction Plans
AARYAN PIC 7.webp

PREVENTIVE MAINTENANCE PLAN

IMPROPER PREVENTIVE MAINTENANCE PLANS LEAD TO FASTER DETERIORATION OF STRUCTURES

A detailed preventive measures list with periodic testing.

WATERPROOFING

COMPLETE SOLUTION TO LEAKAGES BY WATERPROOFING AUDITS AND PMC

Aaryan offers complete end-to-end consulting services, covering basement waterproofing, roof waterproofing, bathroom waterproofing, external wall waterproofing, using the latest waterproofing products and systems, evaluation of competent waterproofing contractors, supervision of works and ultimately a certification process. Waterproofing failures often lead to structural problems and vice versa. Aaryan provides a holistic approach to solve both together.

istockphoto-1257151444-612x612.jpg
WATER1.webp

USING STATE OF THE ART EQUIPMENT

LOCATING THE SOURCE OF WATER LEAKAGE

Combining over 20 different instruments ranging from thermal cameras, moisture meters, locators, and acoustic instruments, our team has the expertise to locate the source of water leakage to a reasonable degree of accuracy. 

CAPTURING REQUIREMENTS ACCURATELY

ESTABLISHING WATER PROOFING SYSTEM REQUIREMENT

Audit waterproofing to check current leaks, materials, warranty, measurement sheets, with on-site tests and analysis

WATER2.webp
WATER3.webp

EACH SYSTEM IN UNIQUE TO THE SITE

IDENTIFICATION OF IDEAL TECHNO COMMERCIAL SYSTEM SUITABLE FOR THE REQUIREMENT

Selection of the right waterproofing system to meet current and future requirements

MAPPING SYSTEM TO MANUFACTURER

SELECTION OF MANUFACTURER PROVIDING THE SELECTED SYSTEM

WATER4.webp
man and pannels

EM-PANELED APPLICATORS

EVALUATION OF AUTHORIZED APPLICATORS EXPERIENCED IN THE SYSTEM

Recommend the set of applicators experienced in executing system of the selected manufacturer

EXTENSIVE CHECKLIST

SUPERVISION OF EXECUTION WITH PERIODIC VISITS AT KEY MILESTONES

Periodic inspection by experts and engineers.  Action points monitoring by back office for compliance

WATER6.webp

STATE OF THE ART INSTRUMENTS

PERIODIC TESTING OF WORKS AND MEASUREMENTS

Untitled design_edited.jpg

Extensive periodic tests to measure and monitor the execution by applicator along with the manufacturer

COMPLIANCE STATEMENT

CERTIFICATION OF SUCCESSFUL COMPLETION OF WORKS

Collect extensive site data, inspection reports, test reports for issuing water proofing certification.

WATER8.webp
WATER9.jpg

DEFINED CHECKLIST FOR MONTHS, QUARTER AND YEAR

PREVENTIVE MAINTENANCE METHODS PROTOCOL

Periodic testing post application, twice a year to ascertain the effectiveness of system. Issues if any are promptly actioned.

PERIODIC CHECKS

PERIODIC EVALUATION OF WATERPROOFING SYSTEM

Periodic checking of weak spots especially pre monsoon to preempt and take preventive action well in time.

WATER10.webp

AS BUILT DRAWINGS

AS BUILT ARCHITECTURAL AND STRUCTURAL DRAWINGS

Image by ThisisEngineering RAEng

Any structural or layout change in the building needs a proper structural drawing to ensure that the modification does not cause any stability issues to the structure.

 

Most of the old structures don't have any drawings on them. Some have only layout plans. There is a requirement for creating as-built drawings for these structures.   

With its range of instruments like total station, rebar scanners, laser meters etc. Aaryan site team prepares as-built architectural and structural drawings, that represent the as-is condition of the building.

Aaryan as-built drawings are used by leading consulting firms, clients and statutory bodies for further analysis and decision-making.

CEILING AUDIT

YOU CAN SAVE A LIFE BY AUDITING THE CONDITION OF THE SLAB
(HIDDEN ABOVE THE FALSE CEILING)

The condition of the ceiling is a major cause of concern as it is prone to falling and injuring the people seriously occupying the space. A chunk of concrete falling from a height of 3 meters (10 feet), weighing a few kgs, can have potentially fatal consequences. 

As the reinforcement gets corroded, it pushes the concrete in an outward direction. With a thin cover concrete (the space between the concrete surface and rebar), the chances of concrete falling off the ceiling increase exponentially with corrosion.

The primary reason for corrosion acceleration is age, carbonation and leakages. 

Aaryan has a unique method to conduct ceiling audits for exposed ceilings and the ones that are covered with false ceilings to ensure the safety of the occupants. this includes visual inspection and special acoustic instruments to assess hard-to-reach areas. At times, co-relation with thermal inspection is also done. 

 

We recommend that ceiling audits be done near all wet areas, common areas and areas prone to leakages.  Buildings that are old, are also in urgent need of ceiling audits as a chunk of concrete could fall on someones head anytime.

false ceiling falling off.png

RENOVATION AUDIT

ENSURE STRUCTUAL AND WATERPROOFING INTEGRITY DURING RENOVATIONS

leaking-roof.jpeg

Renovations by members can damage the structural elements, putting the residents at risk. The waterproofing done by local agencies can cause permanent leakages for other residents. This creates a headache for the building administration and management team. 

Aaryan's in-depth renovation audit ensures that no structural element is damaged and waterproofing is done as per quality standards.

  Using NDT test instruments and drawings, not just by visual observations, Aaryan delivers quality reports that are actionable by residents. 

FORENSIC AUDIT OF BUILDINGS

ROOT CAUSE ANLAYSIS TO DETERMINE REASON OF FAILURE

A disaster like fire, cyclone, loading, vibrations or ageing can damage the structure beyond repair and give rise to claims and counter-claims for losses incurred.  With insurance agencies, brokers, surveyors, and technical experts involved, the forensic analysis conducted by Aaryan provides a correct assessment of the root cause of the damage. 

Depending on the inclusions and exclusions of the insurance policy, the claims are then validated by surveyors and settled by insurance companies.

Aaryan works with leading insurance companies to provide its services in areas related to claims that involve structural, waterproofing, HVAC, stp, plumbing, electrical, and lift-related cases.

images for niche and aaryan  brochures - 2025-03-06T152534_edited.jpg

STRUCTURAL STRENGTHENING

FOR CHANGE OF USE, ADDITIONAL FLOORS, INCREASED LOADING

Image by Tormius

As requirements for the use of space change, the loading on the structure also changes. Typical examples are the installation of new machinery, change of use of a building from say residential to commercial, and addition of floors.

 

Sometimes, the original drawings are not available. In this case, Aaryan  generates the as-built drawings from scratch using its "As Built drawing system"

 

The modeling is done on an as-is basis and then on a to-be basis. the gaps in the modeling are then converted to a strengthening scheme, which is optimized for costs and performance.  

With our in-house testing and systems,  Aaryan provides an end-to-end system for structural strengthening for your structures.